IMMERSION COOLING SERVERS
Immersion cooling involves immersing computer components or entire servers in a thermally, but not electrically, conductive liquid (dielectric coolant). This method is becoming more and more popular due to the need to densify data centers and the increasing power requirements of chips designed by manufacturers. Computer equipment or servers cooled in this manner do not require fans, and the heat exchange between the hot coolant and the cold water circuit is done through a heat exchanger.
Two principles of the immersion cooling technology exist, we already covered them up in other articles: single-phase immersion cooling and two-phase immersion cooling.
2CRSi's Servers Designed for Immersion Cooling
Our immersion cooling servers have been specially designed for this type of cooling:
- All cables are accessible from the front of the server
- The hot spots have been located downwards for more efficiency
- We manufacture our own cables, thinner and more resistant to different fluids
- Chassis are open for better heat exchange
Immersion Cooling 19" Servers

Atlantis 1.4
1U 19” AI server
Available in:
- Designed for single phase immersion cooling
- Up to 4 GPUs
- 1 AMD CPUs (SP5 socket)
- 24 memory slots
Applications:
- HPC
- Rendering
- AI/ML
- GPU virtualization

Atlantis 1.8
2U 19” GPU server
Available in:
- Designed for single phase immersion cooling
- Up to 8 GPUs
- 2 AMD or Intel CPUs (3rd Gen)
- 8 memory slots
Applications:
- HPC
- Rendering
- AI/ML
- GPU virtualization
Immersion Cooling 21" Servers

Atlas 1.8GG
1U 21” with PSU AI server
1U 21” hyper-dense AI server
Available in:
- The first server designed for dual-phase immersion cooling
- Up to 8 NVIDIA GPUs (H200, H100)
- 2 AMD CPUs (SP5 socket)
- 24 memory slots
Applications:
- HPC
- Rendering
- AI/ML
- GPU virtualization

Atlas 1.4G0
1U 21” with PSU AI server
Available in:
- Designed for single phase immersion cooling
- Up to 4 NVIDIA GPUs (H200, H100)
- 1 AMD CPUs (SP5 socket)
- 24 memory slots
Applications:
- HPC
- Rendering
- AI/ML
- GPU virtualization
2CRSi's OCP 21” Servers designed for immersion

OCtoPus 1.4
1OU 21” OCP AI server
Available in:
- OCP inspired
- Designed for single phase immersion cooling
- Up to 4 NVIDIA GPUs (H200, H100)
- 1 AMD CPUs (SP5 socket)
- 24 memory slots
Applications:
- HPC
- Rendering
- AI/ML
- GPU virtualization
2CRSi's Immersion Cooling Tanks Partners

- Shell liquid
- 24U/OU
- Natural convection
- No CDU
- 15’’ or 21’’ form factor
- 32/60kW Cooling
-
Agnostic liquid
- 24/42/84/168U
- Convection with pump
- Internal & External CDU
- 19’’ or 21’’ form factor
- 25/50kW (24)50/180kW (42/84/168)

- Agnostic liquid (Castrol, Shell, Submer Smart Coolant, Lubrizol, ...)
- 6/21/45 U/OU
- Convection with pump
- Internal & External CDU
- 19" or 21" form factor
- 7kW (6U) / 50kW (21U) or 50kW redundant (44U) / 100kW (41U)

-
Agnostic liquid
- 12U/50U/Container
- Convection with pump
- External CDU
- 19’’ and custom form factor
- Up to 150kW
- N+1 Cooling

-
Agnostic liquid
- 24/42U
- Convection with pump
- External CDU
- 19’’ form factor
-
Up to 200kW N+1 Cooling